Topics covered in this article
1. Arch PLC Accessory Kit contents
2. Arch PLC Accessory details
3. Arch PLC Accessory connection instructions
A. Using an AC/DC adapter
B. Using an external DC power source
4. Arch PLC Accessory Kit installation instructions
1. Arch PLC Accessory Kit contents
Beam Break Kit Contents | ||
Item | Qty | Description |
1 | 1 | POD-1C |
2 | 1 | PLC Accessory |
3 | 1 | AC/DC 12V power supply |
4 | 1 | DB-9 cable, 3m |
5 | 4 | POD-1C cover screws |
6 | 3 | Cable tie anchors |
7 | 3 | Zip ties |
IMPORTANT: POD-1C device is programmed specifically for this kit. DO NOT SWAP POD-1C from any other kit.
2. Arch PLC Accessory details
The Arch PLC Accessory is a device that allows tapping of existing signals within a PLC device. It features isolated inputs that drive an opto-isolator to capture the signal. For proper operation, the tapped signal must be directly driven by the PLC and cannot be dry switch contacts. Please see the schematic diagram below.
If the application requires connection to dry switch contacts, then please use our non-isolated GPIO Accessory.